Glass forced circulation solar system for central heating 

CENTRAL SOLAR SYSTEM  WITH GLASS TANK AND COLLECTORS PHAETHON
MODEL CODE TYPE CAPACITY 
IN LT
NUMBER OF
COLLECTORS
SURFACE OF COLLECTORS
SOLAR G16 COPPER 206-111 160 2 3,40 m2
SOLAR G16 COPPER 206-111 XL 160 2 4,00 m2
SOLAR G20 COPPER 206-112 200 2 4,00 m2
SOLAR G20 COPPER 206-112 XL 200 2 4,80 m2
SOLAR G30 COPPER 206-114 300 2 4,80 m2
SOLAR G30 COPPER 206-114 XL 300 3 6,00 m2

 

CENTRAL SOLAR SYSTEM  WITH GLASS TANK AND COLLECTORS ATLAS
MODEL CODE TYPE CAPACITY 
IN LT
NUMBER OF
COLLECTORS
SURFACE OF COLLECTORS
SOLAR G16 COPPER 206-211 160 2 3,16 m2
SOLAR G16 COPPER 206-211 XL 160 2 3,80 m2
SOLAR G20 COPPER 206-212 200 2 3,80 m2
SOLAR G20 COPPER 206-212 XL 200 2 4,60 m2
SOLAR G30 COPPER 206-214 300 2 4,60 m2
SOLAR G30 COPPER 206-214 XL 300 3 5,70 m2

 

Component Central System Description


CONTROLLER FOR SOLAR COLLECTORS WITH CONTROL OF THE BURNER AND 2 SENSORS
These complete systems include the following:
• 2 or 3 SELECTED COLLECTORS PHAETHON or ATLAS 
• 1 or 2 COLLECTOR BASES
• 1 HYDRAULIC SOLAR KIT WITH THERMOSTAT CONTROLLER Mod.Normal
• 1 EXPANSION VESSEL OF SOLAR TYPE
• 1 PRESSURE EXPANSION VESSEL BLUE
• 1 PRESSURE REDUCER WITH HEAVY TYPE MANOMETER
• 1 SENSOR SLEEVE
• 1 CROSS FITTING Φ22 WITH SENSOR AND AIR RELIEF
• 2 or 4 COMPRESSION FITTINGS STRAIGHT Φ22ΧΦ22 
• 2 COMPRESSION FITTINGS END STOP Φ22
• 1 SAFETY VALVE 10 bar
• ANTIFREEZE

Note
The dimensioning of the individual devices and components that compose each standard system (package) referred to herein, is indicative and refers to typical standard installations. In cases where there are particularities or disadvantages (large distance between boiler and solar collectors, great deviation in the orientation of the collectors towards the south, small inclination of collectors, increased demands for hot water, etc.), then the differentiation of the above is required. The technical department of our company is at your disposal to help design and dimension the individual devices of any central solar system installation for hot water production.

 

Technical characteristics of central solar system packages with glass storage tank

TECHNICAL CHARACTERISTICS OF GLASS STORAGE TANK:
• Hot water storage tank, 2mm thick
• 1 or 2 heat exchangers
• Insulation with ecological polyurethane of 65mm thickness
• 4 kw electrical resistance with safety thermostat

TECHNICAL CHARACTERISTICS OF SELECTIVE COLLECTORS

Technical characteristics of collector PHAETHON:
• Frame: aluminum profiles, lateness design with internal corner aluminum links, that ensure the best possible implementation of the framework and the stability of the whole construction.
• Back of collector: from European grey steel, (ral 9006), fully sealed, without screw connections. 
• Glass: security, tempered, 4 mm, of high permeability, with rubber E.P.D.M. for complete sealing.
• Insulation at the back of the collector: Rockwool (d = 50kg / m3) 
• Insulation at the lateral parts: Rockwool (d = 50kg / m3) 
• Absorber: of selective surface, 0.5 mm full plate, constructed by high-tech laser welding
• Absorber piping: copper tubes Ø 8 mm & Ø 22 mm
• Specially designed oval rubber, adapted to copper pipes that connect the collector, to prevent the phenomenon of dilation - contraction.

 

Technical characteristics of collector ATLAS:
• Frame: aluminum profiles, lateness design with external corner aluminum links, that ensure the best possible implementation of the framework and the stability of the whole construction.
• Back of collector: aluminum fitted without auxiliary restraint of screw connections, fully sealed. 
• Glass: security, tempered, 4 mm, of high permeability.
• Insulation at the back of the collector: Rockwool (d = 50kg / m3) 
• Insulation at the lateral parts: Rockwool (d = 50kg / m3) 
• Absorber: of selective surface, 0.5 mm full plate, constructed by high-tech laser welding
• Absorber piping: copper tubes Ø 8 mm & Ø 22 mm

TECHNICAL CHARACTERISTICS OF SOLAR kit & TERMOSTAT CONTROLLER

SOLAR kit
• Circulator
• Return valve (degasser)
• Flowmeter with flow control of 2-12lt / min
• Safety valve 6 Bar with barometer
• Non-return valve
• Temperature indicators at supply and return
• Isolation switches on return and supply
• Fill and evacuation valves
• Supplies dimension Φ22


SOLAR CONTROLLER THERMOSTAT DIFFENTIAL
• 2 commands and 3 temperature sensors
• 2 desired temperatures in the Boiler: one from the sun and the other from the second energy source
• Break function
• Display the measured temperatures on the screen
• Collector overheat protection
• Collector frost protection 
• Diagnosis of sensor damages
• Ability to incorporate into the Solar kit

 

Certified products according to international standards

SONNE cooperations and memberships

Head Offices

39, Chalkidikis str.
14451 Metamorfosi, Athens, Greece

Find us on the map
Contact

Telephone: +30 210 2843376
Fax: +30 210 2841650

Email: info@sonne.gr
Open

Monday- Friday: 8 AM - 4 PM
Saturday- Sunday: closed